Description:

Selection and Use of Rigid Sterilization Containers

Publisher:
Canadian Standards Association / National Standard of Canada

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
Need Help?
1.1 This Standard defines essential elements in the selection, use, and maintenance of rigid sterilization containers. The selection criteria include minimum construction and performance requirements to help health care facilities choose products that are appropriate for their intended use.

1.2 This Standard applies to the following types of rigid sterilization containers: (a) protective organizing cases or trays that require additional wrapping or an additional method of containment for sterilization and maintenance of sterility; (b) rigid sterilization container systems that do not require additional wrapping; and (c) trays intended for use in sterilization processes that do not rely on wrapping, such as emergency (flash) and point-of-use sterilization.

1.3 This Standard sets forth requirements in the following areas: (a) policies and procedures related to the use of rigid sterilization containers; (b) general characteristics, selection, and purchasing of rigid sterilization containers; (c) personnel training and occupational health and safety; (d) matching of containers to their appropriate sterilization methods and cycles; (e) testing prior to use; (f) decontamination, preparation, and assembly of rigid sterilization containers; (g) sterilizer loading and unloading; (h) sterile storage; (i) on-site distribution and off-site transportation of rigid sterilization containers; (j) aseptic presentation and use; and (k) quality assurance.

In addition, this Standard addresses the preparation, handling, and loading of medical devices in containerized sets.

1.4 This Standard does not provide requirements for (a) ongoing sterility assurance programs in health care facilities; or (b) textile packs.

Note: CAN/CSA-Z314.2 and CAN/CSA-Z314.3 provide requirements for ethylene oxide and steam sterilization in health care facilities. CSA Z314.10 provides requirements for the selection and use of reusable surgical textiles.

1.5 In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Legends to equations and figures are considered requirements.


Number of Pages : 60
Published : 07/01/2005

History

CAN/CSA Z314:23
Published Date: 01/23/2023
Canadian medical device reprocessing in all health care settings, Includes Update No. 1 (2024)
$181.5
CAN/CSA Z314-18
Published Date: 02/01/2018
Canadian medical device reprocessing
$158.7
CAN/CSA Z314.10.2-10 (R2015)
Published Date: 02/01/2010
Laundering, maintenance, and preparation of multiple-use gowns, drapes, and wrappers in health care facilities
CAN/CSA Z314.10.1-10 (R2015)
Published Date: 02/01/2010
Selection and use of gowns, drapes, and wrappers in health care facilities
CAN/CSA Z314.15-10 (R2015)
Published Date: 02/01/2010
Warehousing, storage, and transportation of clean and sterile medical devices
CAN/CSA Z314.8-08 (R2013)
Published Date: 03/01/2008
Decontamination of Reusable Medical Devices
CAN/CSA Z314.14-04
Published Date: 07/01/2005
Selection and Use of Rigid Sterilization Containers
CAN/CSA Z314.22-04
Published Date: 07/01/2004
Management of Loaned, Shared, and Leased Medical Devices, Includes Update No. 1 (2006)
CAN/CSA Z314.15-03 (R2008)
Published Date: 06/10/2003
Warehousing, Storage, and Transportation of Clean and Sterile Medical Devices
CAN/CSA Z314.10-03 (R2008)
Published Date: 04/14/2003
Selection, Use, Maintenance, and Laundering of Reusable Textile Wrappers, Surgical Gowns, and Drapes for Health Care Facilities
$27
CAN/CSA Z314.3-01 (R2006)
Published Date: 01/01/2001
Effective Sterilization in Health Care Facilities by the Steam Process
$21.9
CAN/CSA Z314.8-00 (R2005)
Published Date: 06/12/2000
Decontamination of Reusable Medical Devices
CAN/CSA Z314.10-97
Published Date: 03/21/2000
Selection, Use, Maintenance and Laundering of Reusable Textile Wrappers, Surgical Gowns and Drapes for Health Facilities
$11.1
CAN/CSA Z314.3-M91
Published Date: 01/01/1991
Effective Sterilization in Hospitals by the Steam Process
$12.6

Related products

CAN/CSA C22.2 No. 60601-2-6:14 (R2023)
Published Date: 03/01/2014
Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Microwave Therapy Equipment (IEC 60601-2-6:2012, MOD)
$39
CAN/CSA E60335-2-41:24
Published Date: 01/07/2024
Household and similar electrical appliances - Safety - Part 2-41: Particular requirements for pumps (Adopted IEC 60335-2-41:2012, fourth edition,2012-12, with Canadian deviations)
$103.5

Best-Selling Products

UL 1004-10
Published Date: 02/28/2020
Standard for Pool Pump Motors
$150.6
UL 1004-1
Published Date: 09/15/2008
Rotating Electrical Machines - General Requirements
UL 1004-1
Published Date: 09/19/2012
Rotating Electrical Machines - General Requirements
$189.3
UL 1004-2
Published Date: 09/15/2008
Impedance Protected Motors
UL 1004-2
Published Date: 01/10/2014
Impedance Protected Motors
UL 1004-3
Published Date: 09/15/2008
Standard for Thermally Protected Motors